TQ 1620

BIKAI TQ 1620 Triple Quadrupole Mass Spectrometer

BIKAI TQ 1620 is a high-performance triple quadrupole mass spectrometer equipped with a plug-and-play ESI/APCI dual ion source, efficient ion transmission, a 180° curved linear acceleration collision cell, and a highly stable triple quadrupole mass analyzer. It delivers high sensitivity, selectivity, and reliable quantitative performance for demanding LC-MS/MS applications. The system supports MS/MS, MRM, SIM, Full Scan, Product Ion Scan, Precursor Ion Scan, and Neutral Loss Scan, with a mass range of m/z 5–2000 and a scanning speed of up to 10,000 amu/s. In ESI+ mode, reserpine MRM 609/195 achieves an instrument detection limit (IDL) of <6 fg and S/N >200,000:1. Automated tuning, calibration, syringe pump control, switching valve control, and comprehensive data processing functions further simplify routine operation. The system uses high-purity nitrogen for both nebulization and collision gas and can be equipped with a nitrogen generator, reducing the need for additional gas cylinders. It is well suited for pharmaceutical analysis, food safety, environmental testing, and research applications.

Parameter Specification
Mass Spectrometer Type Triple Quadrupole Mass Spectrometer
Ion Source ESI + APCI dual ion source
Ion Source Switching Plug-and-play design; replacement in approx. 30 seconds
ESI Flow Rate 5 μL/min – 3 mL/min
APCI Flow Rate 200 – 2000 μL/min
Maximum Heating Temperature 750 °C
Mass Range m/z 5–2000
Scanning Speed Up to 10,000 amu/s
Mass Resolution <0.8 amu
Mass Stability 0.1 amu / 24 h
Dynamic Range 4 orders of magnitude
MRM Sensitivity S/N >200,000:1 for reserpine, MRM 609/195
Instrument Detection Limit (IDL) <6 fg for reserpine, ESI+
Scan Modes Full Scan, SIM, Product Ion, Precursor Ion, Neutral Loss, MRM
MS/MS Function MS and MS/MS
Reproducibility Peak area RSD <5.0%; retention time RSD <5.0%
Collision Cell 180° curved linear acceleration collision cell
Gas System High-purity nitrogen for nebulization and collision gas
Gas Supply Nitrogen generator compatible; no additional collision-gas cylinder required
Automatic Syringe Pump Built-in software-controlled syringe pump
Switching Valve Built-in software-controlled six-way valve
Vacuum System Mechanical pump + integrated multi-port turbo molecular pump
Mechanical Pumping Speed 40 m³/h
Turbo Molecular Pump Integrated, oil-free, air-cooled
Data System Windows 10 or above, 64-bit
Software Language Chinese / English
Data Processing Qualitative and quantitative analysis, MRM, batch processing, peak statistics, S/N calculation, and automated report generation

 